Part Number Hot Search : 
TB220F S13402 2SD17 111X20 G300Q ITA18B3 AD9652 UM7301
Product Description
Full Text Search
 

To Download T6615-10KF Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  telaire t6615 sensor dual channel module compact co 2 module designed to integrate into existing controls and equipment the telaire ? t6615 dual-channel co 2 module is designed to meet the volume, cost, and delivery expectations of original equipment manufacturers (oems). features ? an affordable gas sensing solution for oems. ? a reliable sensor design based on 15 years of engineering and manufacturing expertise. ? flexible co 2 sensor platform designed to interact with other microprocessor devices. ? dual-channel optical system and three-point calibration process for enhanced stability, accuracy and reliability. ? designed for applications where abc logic cannot be used ? sensor may be feld calibrated a mphenol advanced sensors ?
telaire t6615 sensor module specifcations method dual-channel non dispersive infrared (ndir), gold plated optics, diffusion or fow through sampling. measurement range 0 to 2000 ppm 0 to 5000 ppm 0 to 10,000 ppm 0 to 50,000 ppm dimensions 2.25 in x 1.365 in x 0.60 in (57.15 mm x 34.67 mm x 15.24 mm) accuracy* 75 ppm or 10% of reading (whichever is greater) temperature dependence 0.2% fs per c stability over life of sensor (10 years) < 5% of fs or <10% reading annual pressure dependence 0.135% of reading per mm hg response time < 2 minutes for 90% step change typical warm up time ? < 2 minutes (operational) ? 10 minutes (maximum accuracy) operating conditions ? 32f to 122f (0c to 50c) ? 0 to 95% rh, non condensing storage conditions -40f to 158f (-40c to 60c) (non condensating) output digital uart @ 19200 baud (please call for detailed product specifcations). analog 0 to 4 vdc power supply requirements 5 vdc regulated (5%) power consumption ? 0.90 watts peak ? 0.165 watts average interface connections designed for 12 pin male header with 0.1 in (2.54 mm) spacing. header not included. flow rates (via flow ports) flow through version: 50 cc/min maximum diffusion version: 80 - 120 cc/min warranty terms 12 months * handling and oem assembly may affect factory calibration. 0.38 in (9.65 mm) 1.24 in (31.5 mm) 1.365 in (34.67 mm) 2.25 in (57.15 mm) 1.125 in (28.575 mm) 0.15 in (3.81 mm) 1.75 in (44.45 mm) 2 mounting holes ?.105 (2.667) 0.062 in (0.1575 mm) 0.54 in (13.7 mm) 0.60 in (15.24 mm)
sensor accuracy and field calibration the t6615 is a dual channel sensor. the two channels can be described as a co 2 channel that measures gas concentration and a reference channel that measures the sensor signal intensity. the t6615 performs periodic self-calibrations using the reference channel. the self calibrations are approximately every 24 hours but can also be initiated by sending a command (see communication protocol). self calibrations should not be performed during the warm-up period. during the self calibration the sensor ppm reading is frozen, it will not react to changing co 2 . the calibration time is adjustable but nominally two minutes. over time the minor electrical and mechanical changes can affect the sensor accuracy. with the exception of operation in harsh environments the rate of signal change is a decaying function, thus the longer the sensor operates the more stable it will become. the reference channel will correct for these changes over time. telaire recommends periodic gas calibration depending on the application accuracy requirements. while the reference channel corrects for changes over time, a feld calibration using nitrogen gas will immediately restore the highest level of accuracy. module t6615-f (flow through) the diffusion membrane is replaced with a non- permeable seal. the two fow ports can be used for fow through sampling. flow rate of 50 cc/min recommended. handling and installation the t6615 co 2 oem modules are infrared gas sensors on a printed circuit board and should be treated carefully. precautions should be taken to observe specifed limits and prevent damage from electrostatic discharge or rough handling. please refer to ansi/esd s20. 20-1999 for more information on preventing esd damage and ipc 610 rev d for more information on proper electronic assembly practices. available models part number sampling method measurement range t6615 diffusion 0-2,000 ppm t6615-5k diffusion 0-5,000 ppm t6615-10k diffusion 0-10,000 ppm t6615-50k diffusion 0-50,000 ppm t6615-f flow through 0-2,000 ppm t6615-5kf flow-through 0-5,000 ppm T6615-10KF flow-through 0-10,000 ppm t6615-50kf flow-through 0-50,000 ppm t6615-r12 diffusion, 12 second rate 0-2,000 ppm pin designations connector pinout function a tx (uart) b rx (uart) c v+ (5 vdc) 1 v+ (5 vdc) 2 gnd 3 gnd 4 av out (0 to 4 vdc) 5 no connect 6 no connect 7 no connect 8 no connect 9 no connect 10 tx (uart) 11 rx (uart) 12 gnd
aas-920-474d-03/2014 www.amphenol-sensors.com ? 2014 amphenol corporation. all rights reserved. specifcations are subject to change without notice. other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. a mphenol advanced sensors


▲Up To Search▲   

 
Price & Availability of T6615-10KF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X